FACTORY DIRECT DISPATCH Tuzla OSB & Dilovasi Machinery Zone, Istanbul / Kocaeli, Turkey
TURKISH HEAVY MANUFACTURING • ISO 8528 & CE COMPLIANT

HEAVY-DUTY INDUSTRIAL DIESEL GENERATOR SETS
20 kVA TO 1,000 kVA

Factory-direct European and Heavy-Commercial diesel generator sets engineered with authentic Perkins (UK), Volvo Penta (Sweden), Baudouin (France), and Ricardo engines. Equipped with 50°C tropical copper-brass radiators, 2.0 mm hot-dip galvanized acoustic enclosures (68 dBA @ 7m), and Deep Sea Electronics DSE7320 MKII digital telemetry.

Download 2026 PDF Catalog (4.8 MB)

100% FAT

Full Load Bank Tested

50°C

Tropical Heavy Radiator

68 dBA

2.0mm Galvanized Canopy

< 15 MIN

Factory Desk Response SLA
ASKGEN Soundproof Canopy Diesel Generator Set
CANOPY SOUNDPROOF SERIE
AUTHENTIC OEM ENGINE & COMPONENT PARTNERS
PERKINS UNITED KINGDOM
VOLVO PENTA SWEDEN
BAUDOUIN FRANCE
RICARDO HEAVY DUTY
MECC ALTE ITALY
DEEP SEA UK DSE

FACTORY DIRECT GENERATOR LINES (20 – 1,000 kVA)

Select an engine brand to review ratings, fuel consumption curves, alternator pairings, and technical datasheets. All units assembled in our Tuzla and Dilovasi facilities under strict ISO 8528-1 manufacturing tolerances.

Perkins 100 kVA Diesel Generator
100 kVA / 80 kW
PERKINS 1104A-44TG2 • UK

ASK-P100 PERKINS SERIES

Prime: 90 kVA | Standby: 100 kVA

Turbocharged 4-cylinder mechanical injection engine. Unrivaled cold start reliability, widely regarded as the gold standard for hospital ICU backup and commercial complexes.

Displacement:4.4 Liters
Fuel Burn (75% Load):16.5 L/hr
Alternator:Mecc Alte ECP34-1S/4
Dimensions (Canopy):2400 x 1000 x 1650 mm
Dry Weight:1,420 kg
WhatsApp
Volvo Penta 250 kVA Diesel Generator
250 kVA / 200 kW
VOLVO TAD734GE • SWEDEN

ASK-V250 VOLVO PENTA

Prime: 227 kVA | Standby: 250 kVA

Electronic common-rail inline 6-cylinder engine with EMS 2 digital governing. ISO 8528 G3 transient load acceptance, ideal for data centers and precision automated plants.

Displacement:7.15 Liters
Fuel Burn (75% Load):38.2 L/hr
Alternator:Mecc Alte ECO38-2S/4
Dimensions (Canopy):3400 x 1200 x 1950 mm
Dry Weight:2,650 kg
WhatsApp
Baudouin 275 kVA Diesel Generator
275 kVA / 220 kW
BAUDOUIN 6M16G • FRANCE

ASK-B275 BAUDOUIN SERIES

Prime: 250 kVA | Standby: 275 kVA

High-durability French marine heritage cast-iron block. Exceptional tolerance to lower-grade sulfur diesel fuels, engineered for 24/7 continuous operation in heavy mining and quarrying.

Displacement:9.72 Liters
Fuel Burn (75% Load):41.8 L/hr
Alternator:Stamford / Mecc Alte
Dimensions (Canopy):3600 x 1250 x 2050 mm
Dry Weight:2,980 kg
WhatsApp
Ricardo 150 kVA Diesel Generator
150 kVA / 120 kW
RICARDO R6105 • HEAVY COMM

ASK-R150 RICARDO VALUE

Prime: 136 kVA | Standby: 150 kVA

Mechanical fuel pump and robust mechanical governing. Maximum capital cost efficiency, ideal for agricultural water pump stations, municipal contractors, and standby power.

Displacement:6.75 Liters
Fuel Burn (75% Load):24.5 L/hr
Alternator:Brushless 4-Pole IP23
Dimensions (Canopy):2900 x 1100 x 1750 mm
Dry Weight:1,780 kg
WhatsApp
Perkins 500 kVA Heavy Diesel Generator
500 kVA / 400 kW
PERKINS 2506A • UK

ASK-P500 PERKINS HEAVY

Prime: 455 kVA | Standby: 500 kVA

Heavy-duty 15-liter inline 6-cylinder engine with MEUI electronic unit injectors. Delivers exceptional power density and rapid step-load capability for high-rise towers and industrial complexes.

Displacement:15.2 Liters
Fuel Burn (75% Load):76.0 L/hr
Alternator:Mecc Alte ECO40-3S/4
Dimensions (Canopy):4500 x 1600 x 2300 mm
Dry Weight:4,850 kg
WhatsApp
Baudouin 1000 kVA Containerized Generator
1,000 kVA / 800 kW
BAUDOUIN 12M33 • FRANCE

ASK-B1000 MEGAWATT CLASS

Prime: 910 kVA | Standby: 1,000 kVA

V12 electronic common rail twin-turbo engine mounted in a dedicated 20-foot ISO acoustic container. Designed for continuous grid synchronization, microgrids, and prime power plants.

Displacement:33.0 Liters (V12)
Fuel Burn (75% Load):152.0 L/hr
Alternator:Leroy Somer / Mecc Alte
Dimensions (Container):6058 x 2438 x 2591 mm
Dry Weight:9,850 kg
WhatsApp

TECHNICAL ENGINE COMPARISON MATRIX

Compare our 4 engine platforms side-by-side to match your site requirements, fuel availability, maintenance resources, and lifecycle operating costs.

Evaluation Parameter Perkins (UK) Volvo Penta (Sweden) Baudouin (France) Ricardo Series
Platform Tier TIER 1 GLOBAL TIER 1 GLOBAL HEAVY INDUSTRIAL COMMERCIAL VALUE
Country of Design Peterborough, United Kingdom Gothenburg, Sweden Cassis, France Ricardo Tech Architecture
Governing Standard ISO 8528 G2 / G3 Class ISO 8528 G3 (EMS 2 Electronic) ISO 8528 G2 / G3 Class ISO 8528 G2 Mechanical
Transient Step-Load 70% - 80% Single Step 85% - 100% Rapid Step 75% - 85% Single Step 60% - 70% Single Step
Oil Change Interval 500 Hours 500 Hours (VDS-3) 500 Hours 250 - 300 Hours
Sulfur Fuel Tolerance Standard Euro / GCC Diesel High Purity Required High Tolerance (Marine Spec) High Tolerance
Global Parts Network Global 180+ Countries Global 130+ Countries 100+ Countries (Rapid Export) Standard Global Supply
Factory Warranty 2 Years / 1,000 Hours 2 Years / 1,000 Hours 2 Years / 1,000 Hours 1 Year / 1,000 Hours
Recommended Usage Hospitals, Airports, Telecom Data Centers, Precision Plants Continuous Mining, 24/7 Prime Standby, Construction, Farms

50°C GCC & SAHARAN HEAVY DESERT SPECIFICATION

Standard European generators derate by 15% to 30% when operating above 40°C. ASKGEN units engineered for the Middle East and Africa feature oversized thermal dissipation and dual filtration systems.

RAD

50°C Tropical Radiator

Oversized heavy copper-brass core radiator with mechanical pusher fan. Engineered to deliver 100% prime output at 50°C ambient temperatures in Saudi Arabia, Iraq, UAE, and Sudan without thermal derating.

AIR

Dual Cyclone Sand Filters

Heavy-duty centrifugal dust & sand pre-cleaner filtration. Traps up to 98% of airborne particulate matter before reaching the primary engine intake filters, preventing cylinder liner scoring.

STL

2.0mm Galvanized Steel

Electro-galvanized cold-rolled sheet steel enclosure with 1,000-hour salt-spray tested polyester powder coating. Weatherproof IP54 seals prevent fine dust ingress during haboob dust storms.

DSE

DSE 7320 MKII Telemetry

Deep Sea Electronics auto mains failure controller with RS485 Modbus RTU telemetry. Real-time remote cloud monitoring of oil pressure, engine temp, load kW, and automatic generator exercising.

CONTRACTOR GENERATOR SIZING CALCULATOR

Calculate starting inrush current, motor multipliers, and recommended generator kVA ratings based on your site application and starting method.

PROJECT LOAD PARAMETERS

Min: 15 kW 120 kW Max: 800 kW
RECOMMENDED SIZING
Recommended Generator Capacity
180 kVA
Continuous Prime: 144 kW | Standby: 200 kVA
  • Motor Starting Inrush: 225 kVA
  • Estimated Fuel Burn (75% Load): 28.5 L/hr
  • Recommended Engine: Perkins 1106A / Baudouin 6M16
  • Suggested Alternator: Mecc Alte / Stamford Class H

Sizing calculated according to ISO 8528-1 power factor standards with 20% safety margin.

100% FACTORY ACCEPTANCE TESTING (FAT)

Every ASKGEN diesel generator undergoes rigorous load bank verification at our Tuzla assembly plant prior to export packing. Third-party inspections (SGS, Bureau Veritas, TÜV SÜD) welcome.

01

0% – 50% Cold Step Load

Validation of cold-start responsiveness, lubrication pressure buildup, fuel rail priming, and alternator residual excitation within 10 seconds of cranking.

02

75% – 100% Prime Load Test

Continuous 2-hour resistive and inductive load bank verification. Thermal equilibrium check on copper windings, coolant heat dissipation, and exhaust gas backpressure.

03

110% Overload Test

Mandatory 1-hour 110% standby overload verification to ISO 8528-5. Monitoring alternator AVR voltage stability (±1.0%) and electronic governor frequency dip (<3%).

04

Safety Shutdown Verification

Simulated low oil pressure, high coolant temperature, overspeed, underspeed, and reverse power relay trips. Certified FAT certificate stamped and packed with unit.

CONTAINER STUFFING & LOGISTICS MATRIX

Direct multimodal dispatch via Istanbul (Ambarli), Mersin, and Izmit ports, or international TIR road transport directly to GCC and European borders.

CONTAINER LOADING SCHEDULE

Genset Power Range 20' GP Container 40' HC Container
20 kVA – 50 kVA 4 Units 8 – 10 Units
75 kVA – 150 kVA 2 Units 4 – 6 Units
200 kVA – 350 kVA 1 Unit 2 – 3 Units
400 kVA – 600 kVA 1 Unit (Open Skid) 2 Units (Canopy)
700 kVA – 1000 kVA Open Top / Flat Rack 1 Containerized Unit

All units packed with heavy polyethylene moisture barrier, wooden base skid fumigation (ISPM-15 compliant), and steel corner protectors.

REGIONAL TRANSIT TIMES

Jeddah Islamic Port (Saudi Arabia)
7 – 9 Days Transit
Direct Sea Freight (Mersin Port)
Alexandria Port (Egypt)
3 – 5 Days Transit
Direct Feeder Vessel
Jebel Ali Port, Dubai (UAE)
12 – 14 Days Transit
Ocean Freight (Ambarli Port)
Rotterdam / Antwerp (Europe)
8 – 10 Days Transit
Direct North Sea Service
Riyadh & Dammam (KSA)
6 – 8 Days Transit
Overland TIR Road Transport
Erbil & Baghdad (Iraq)
3 – 5 Days Transit
Habur Border TIR Road Transport
OFFICIAL 2026 TECHNICAL DOCUMENTATION

DOWNLOAD COMPLETE ASKGEN INDUSTRIAL CATALOG

Includes full dimensional engineering drawings, wiring schematics, fuel burn curves, ISO 8528 certification details, and canopy noise attenuation specifications.

FORMAT: PDF SIZE: 4.8 MB EDITION: 2026 GLOBAL EXPORT
Download Catalog PDF

AUTHORIZED EXPORT SALES DESK

Connect directly with our Senior Export Desk for proforma invoices, EUR.1 movement certificates, factory inspection scheduling, and urgent project tenders.

ONLINE • SENIOR EXPORT DESK

Musab K.

Head of Global Export Operations
  • Direct Mobile: +90 530 651 60 06
  • Official Email: hello@kaskazada.com
  • Assembly Facility: Tuzla OSB / Dilovasi Machinery Zone, Turkey
  • Response SLA: < 15 Minutes for Technical Inquiries
  • Languages: English, Turkish, Arabic (Commercial Desk)
Chat on WhatsApp Call Direct
WhatsApp Desk