Factory-direct European and Heavy-Commercial diesel generator sets engineered with authentic Perkins (UK), Volvo Penta (Sweden), Baudouin (France), and Ricardo engines. Equipped with 50°C tropical copper-brass radiators, 2.0 mm hot-dip galvanized acoustic enclosures (68 dBA @ 7m), and Deep Sea Electronics DSE7320 MKII digital telemetry.
Select an engine brand to review ratings, fuel consumption curves, alternator pairings, and technical datasheets. All units assembled in our Tuzla and Dilovasi facilities under strict ISO 8528-1 manufacturing tolerances.
Turbocharged 4-cylinder mechanical injection engine. Unrivaled cold start reliability, widely regarded as the gold standard for hospital ICU backup and commercial complexes.
| Displacement: | 4.4 Liters |
| Fuel Burn (75% Load): | 16.5 L/hr |
| Alternator: | Mecc Alte ECP34-1S/4 |
| Dimensions (Canopy): | 2400 x 1000 x 1650 mm |
| Dry Weight: | 1,420 kg |
Electronic common-rail inline 6-cylinder engine with EMS 2 digital governing. ISO 8528 G3 transient load acceptance, ideal for data centers and precision automated plants.
| Displacement: | 7.15 Liters |
| Fuel Burn (75% Load): | 38.2 L/hr |
| Alternator: | Mecc Alte ECO38-2S/4 |
| Dimensions (Canopy): | 3400 x 1200 x 1950 mm |
| Dry Weight: | 2,650 kg |
High-durability French marine heritage cast-iron block. Exceptional tolerance to lower-grade sulfur diesel fuels, engineered for 24/7 continuous operation in heavy mining and quarrying.
| Displacement: | 9.72 Liters |
| Fuel Burn (75% Load): | 41.8 L/hr |
| Alternator: | Stamford / Mecc Alte |
| Dimensions (Canopy): | 3600 x 1250 x 2050 mm |
| Dry Weight: | 2,980 kg |
Mechanical fuel pump and robust mechanical governing. Maximum capital cost efficiency, ideal for agricultural water pump stations, municipal contractors, and standby power.
| Displacement: | 6.75 Liters |
| Fuel Burn (75% Load): | 24.5 L/hr |
| Alternator: | Brushless 4-Pole IP23 |
| Dimensions (Canopy): | 2900 x 1100 x 1750 mm |
| Dry Weight: | 1,780 kg |
Heavy-duty 15-liter inline 6-cylinder engine with MEUI electronic unit injectors. Delivers exceptional power density and rapid step-load capability for high-rise towers and industrial complexes.
| Displacement: | 15.2 Liters |
| Fuel Burn (75% Load): | 76.0 L/hr |
| Alternator: | Mecc Alte ECO40-3S/4 |
| Dimensions (Canopy): | 4500 x 1600 x 2300 mm |
| Dry Weight: | 4,850 kg |
V12 electronic common rail twin-turbo engine mounted in a dedicated 20-foot ISO acoustic container. Designed for continuous grid synchronization, microgrids, and prime power plants.
| Displacement: | 33.0 Liters (V12) |
| Fuel Burn (75% Load): | 152.0 L/hr |
| Alternator: | Leroy Somer / Mecc Alte |
| Dimensions (Container): | 6058 x 2438 x 2591 mm |
| Dry Weight: | 9,850 kg |
Compare our 4 engine platforms side-by-side to match your site requirements, fuel availability, maintenance resources, and lifecycle operating costs.
| Evaluation Parameter | Perkins (UK) | Volvo Penta (Sweden) | Baudouin (France) | Ricardo Series |
|---|---|---|---|---|
| Platform Tier | TIER 1 GLOBAL | TIER 1 GLOBAL | HEAVY INDUSTRIAL | COMMERCIAL VALUE |
| Country of Design | Peterborough, United Kingdom | Gothenburg, Sweden | Cassis, France | Ricardo Tech Architecture |
| Governing Standard | ISO 8528 G2 / G3 Class | ISO 8528 G3 (EMS 2 Electronic) | ISO 8528 G2 / G3 Class | ISO 8528 G2 Mechanical |
| Transient Step-Load | 70% - 80% Single Step | 85% - 100% Rapid Step | 75% - 85% Single Step | 60% - 70% Single Step |
| Oil Change Interval | 500 Hours | 500 Hours (VDS-3) | 500 Hours | 250 - 300 Hours |
| Sulfur Fuel Tolerance | Standard Euro / GCC Diesel | High Purity Required | High Tolerance (Marine Spec) | High Tolerance |
| Global Parts Network | Global 180+ Countries | Global 130+ Countries | 100+ Countries (Rapid Export) | Standard Global Supply |
| Factory Warranty | 2 Years / 1,000 Hours | 2 Years / 1,000 Hours | 2 Years / 1,000 Hours | 1 Year / 1,000 Hours |
| Recommended Usage | Hospitals, Airports, Telecom | Data Centers, Precision Plants | Continuous Mining, 24/7 Prime | Standby, Construction, Farms |
Standard European generators derate by 15% to 30% when operating above 40°C. ASKGEN units engineered for the Middle East and Africa feature oversized thermal dissipation and dual filtration systems.
Oversized heavy copper-brass core radiator with mechanical pusher fan. Engineered to deliver 100% prime output at 50°C ambient temperatures in Saudi Arabia, Iraq, UAE, and Sudan without thermal derating.
Heavy-duty centrifugal dust & sand pre-cleaner filtration. Traps up to 98% of airborne particulate matter before reaching the primary engine intake filters, preventing cylinder liner scoring.
Electro-galvanized cold-rolled sheet steel enclosure with 1,000-hour salt-spray tested polyester powder coating. Weatherproof IP54 seals prevent fine dust ingress during haboob dust storms.
Deep Sea Electronics auto mains failure controller with RS485 Modbus RTU telemetry. Real-time remote cloud monitoring of oil pressure, engine temp, load kW, and automatic generator exercising.
Calculate starting inrush current, motor multipliers, and recommended generator kVA ratings based on your site application and starting method.
Sizing calculated according to ISO 8528-1 power factor standards with 20% safety margin.
Every ASKGEN diesel generator undergoes rigorous load bank verification at our Tuzla assembly plant prior to export packing. Third-party inspections (SGS, Bureau Veritas, TÜV SÜD) welcome.
Validation of cold-start responsiveness, lubrication pressure buildup, fuel rail priming, and alternator residual excitation within 10 seconds of cranking.
Continuous 2-hour resistive and inductive load bank verification. Thermal equilibrium check on copper windings, coolant heat dissipation, and exhaust gas backpressure.
Mandatory 1-hour 110% standby overload verification to ISO 8528-5. Monitoring alternator AVR voltage stability (±1.0%) and electronic governor frequency dip (<3%).
Simulated low oil pressure, high coolant temperature, overspeed, underspeed, and reverse power relay trips. Certified FAT certificate stamped and packed with unit.
Direct multimodal dispatch via Istanbul (Ambarli), Mersin, and Izmit ports, or international TIR road transport directly to GCC and European borders.
| Genset Power Range | 20' GP Container | 40' HC Container |
|---|---|---|
| 20 kVA – 50 kVA | 4 Units | 8 – 10 Units |
| 75 kVA – 150 kVA | 2 Units | 4 – 6 Units |
| 200 kVA – 350 kVA | 1 Unit | 2 – 3 Units |
| 400 kVA – 600 kVA | 1 Unit (Open Skid) | 2 Units (Canopy) |
| 700 kVA – 1000 kVA | Open Top / Flat Rack | 1 Containerized Unit |
All units packed with heavy polyethylene moisture barrier, wooden base skid fumigation (ISPM-15 compliant), and steel corner protectors.
Includes full dimensional engineering drawings, wiring schematics, fuel burn curves, ISO 8528 certification details, and canopy noise attenuation specifications.
Connect directly with our Senior Export Desk for proforma invoices, EUR.1 movement certificates, factory inspection scheduling, and urgent project tenders.